Kein Strahl · Laser und Leistung
Jede Zeile ist das Ergebnis — oder die Maßnahme, die es geklärt hat — aus einem echten Serviceeinsatz. Stammt die Notiz aus einer chinesischen Aufzeichnung, steht das Original darunter.
Praxishinweise werden in der Sprache zitiert, in der sie verfasst wurden.
10 Praxishinweise zu diesem Thema
Keine Notiz in diesem Thema passt zu diesem Stichwort.
- Power reads normal and nothing comes out. Check the spot-shot parameter first — the source will not emit unless the pulse frequency is set correctly.
- Parameters and configuration all check out and it still will not emit. Take a multimeter to the PWM and DA outputs on the adapter board. P+/P- carry PWM: with DIP 1 up and 2 down, 100% PWM is 22 V and 50% is 11 V; with DIP 1 down and 2 up, 100% is 4 V and 50% is 2 V, and so on. D1 and D2 carry DA1 and DA2. The value shown in the control-card monitor must match what you measure — if it does not, compare the reading with the cable connected and disconnected to localise the fault.
- Everything above checks out and the shutter still will not open — this is beyond the machine builder; escalate to the laser manufacturer.
- The source emits even when no PWM modulation signal is present. That is a laser-side fault — have the laser vendor look at it.
- The laser never sees the adapter board's output signal. Check the signal wiring for poor contact; if it still fails, contact the laser vendor.
- If nothing else clears it, try a 1 kOhm resistor wired in parallel across P+ and P-.
- External interference is corrupting the modulation signal the laser receives — inspect the modulation signal cable.
- On YLS sources an indicator lamp confirms the shutter has actually opened — use it to separate a control fault from a shutter fault.
- Newer sources may have changed their timing. Prefer network-communication control over the hardwired interface when retrofitting.
- Beam drops out or a cut is skipped occasionally during a job — work back through the interlock, shutter and modulation chain rather than touching process parameters.
Dasselbe Problem an Ihrer Maschine? Schicken Sie ein Video — ich sage Ihnen, was Sie zuerst prüfen sollten.